Nuclear Magnetic Resonance

Main activities

  • Development, acquisition, interpretation and manual-fine tuning of NMR data related, but not limited to:
    1. (1) structural characterization of organic and inorganic compounds;
      (2) compositional profiling of complex mixtures;
      (3) quality control;
      (4) quantitative analyses;
      (5) purity determination;
      (6) molecular dynamics and kinetic monitoring of reactions;
  • Provide in-house researchers, graduate, post-graduate students and external users with access to know-how, technology, and state-of-the-art infrastructure for the study of biological macromolecules and their complexes in complex media, molecular interactions and ligand recognition events in a wide range of chemical and biochemical systems;
  • Support the rational design of molecules and (bio)materials with fine-tuned physicochemical properties and of innovative (and cleaner) synthetic routes with enhanced stereoselectivity and applicability in the field of biomedical, agricultural, environmental and food research;
  • Bring synergy towards using NMR spectroscopy and computational methods to probe energetics, structural rearrangements, and conformational fluctuations in allosteric systems, for bioengineering, de novo protein design and drug discovery purpose.
  • The Nuclear Magnetic Resonance Laboratory at UP is part of the Portuguese NMR Network: www.ptnmr.web.ua.pt

    Contact (lrmn@cemup.up.pt)

    Experimental details

  • The three spectrometers are designed for the analysis of samples in the liquid phase and are equipped with variable temperature units, ranging from -150ºC to 180°C;
  • The most common NMR analysis are 1D and 2D experiments in which the signals of the nuclei are analysed, depending on the used probe, and in the case of 2D experiments, it is also possible to look for the correlations between the different studied nuclei;
  • Samples for analysis must be delivered in the liquid phase, with adequate identification. The samples must be delivered in appropriate tubes (quartz), compatible with the frequency of the equipment (400 or 600 MHz) and with a diameter of 5 mm. The solutions should be prepared in deuterated solvents and must be completely soluble in the selected solvent. The ideal amount of sample is 5 - 10 mg for 1H analysis and above 20 mg for 13C analysis. However, it will depend on sensitivity, the isotopic abundance, the nuclei to analyse, the instrument sensitivity, the spectrometer frequency, and the kind of analysis required;
  • The minimum sample volume required is 600 µL, for a tube length of 140 mm. The resistance of the tube must be checked, always, before sample preparation, since it can break inside the instrument during analysis causing serious equipment damage;
  • Long experiments are usually performed overnight or during the weekend.
  • Equipment & software

    ASCEND 600 MHz

    AVANCE III 400 MHz

    ASCEND III 400 MHz

    SOFTWARE

    SUPPORTED BY: